Product Overview
The LayerZero eRDP-FS (eRDP-1) is a web-enabled remote distribution panel (eRDP) with subfeed distribution. It is a MIMO configuration (multiple inputs, multiple outputs), meaning that it can have multiple input power sources and multiple output circuits. The eRDP is ideal for applications that require high-reliability power distribution in a space-saving design.
The core functionality of the LayerZero eRDP is to distribute power to a large number of circuits. It can accommodate subfeed circuit breakers, including both finger-safe and non-finger-safe breakers. This makes it ideal for applications with high power requirements, such as data centers and large industrial facilities.
The eRDP also features a number of safety features, including SafePanel® distribution, dead front doors, no exposed live parts (NELP) and polycarbonate windows. These features help to protect users and equipment from electrical hazards.
If you are looking for a high-reliability, safe, and versatile power distribution solution, the LayerZero eRDP is a great option.
Documents and Downloads
A one line diagram is a symbolic representation of three-phase electric power systems, depicting the paths for power flow between entities of the power distribution system.
One Line
A product outline is a technical engineering drawing showing mechanical characteristics of our products.
Product Outline
Product Specifications
Physical Specifications
Dimensions | 88" x 36" x 36" (2240 mm x 905 mm x 905 mm) |
Weight | 674 lbs (306 kg) |
Clearances | Front 36” [915mm] Rear 0 Left 1” [25mm] Right 1” [25mm] Top 18” [457mm] |
Color | Gray, Black |
Warranty | One-Year Limited Warranty |
CSA Rating | Certified to CSA STD C22.2#29 |
UL Rating | Conforms to UL STD 67 |
Distribution Type | Subfeed Distribution |
System Specifications
System Input Voltage | 600V, 3-Phase, 3-Wire + Ground |
System Output Voltage | 120/208V, 3-phase, 4-wire + Ground |
System Output Voltage - 1st Alternate | No |
System Output Voltage - 2nd Alternate | No |
Transformer Size | 150kVA |
Secondary Neutral Rating | 200% |
eSTS Integration | No |
Input Feeder Terminations | Two-hole Compression Lug Terminals |
Presence of Primary Side Distribution | No |
Transformer Input Current Rating | 144A |
Transformer Output Current Rating | 416A |
Presence of Secondary Side Distribution | Yes |
Secondary Distribution Side | Both |
Secondary Distribution Orientation | Side-facing |
Distribution Type | 42-pole Branch Circuit Distribution and Subfeed Breakers |
Total Quantity of Branch Circuit Panel Boards | 4 |
Total Quantity of 225A Branch Circuit SafePanels® | 4 |
Total Quantity of 400A Branch Circuit SafePanels® | 0 |
Exposed Live Parts or No Exposed Live Parts | Exposed Live Parts (ELP) |
Subfeed Circuit Breaker Type | Subfeed Distribution |
Secondary Subfeed Type | 1200A SafePanel® |
Secondary Subfeed Panel Board Quantity | 1 |
Presence of Primary Main Circuit Breaker | Yes |
Presence of Primary Auxiliary Circuit Breaker | No |
Sync Check Relay Required | N/A |
Presence of Kirk Key Interlock | N/A |
Primary Main Circuit Breaker (CB601)
Frame Rating | 250 |
Circuit Breaker Type | Electronic Trip (LSIG) |
Circuit Breaker Mounting Type | Fixed |
Max Steady State Rating | 250 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 600VAC |
Presence of Shunt Trip | 24VDC |
Presence of CB Position Indications | Yes - wired to terminal blocks |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Transformer (T620)
Transformer size | 150 |
Material | Copper |
k-Factor | k-20 |
Efficiency Class | Per DOE 2016 |
Temperature Rise | 150 |
Inrush | 5X Max |
Nominal Impedance | 5.5 |
Secondary Main Circuit Breaker (CB701)
Frame Rating | 600 |
Circuit Breaker Type | Electronic Trip (LSI) |
Circuit Breaker Mounting Type | Fixed |
Max Steady State Rating | 600 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Branch Circuit Panel Board 1 Main Circuit Breaker (CB821)
Frame Rating | 250 |
Circuit Breaker Type | Electronic Trip (LS/I) |
Circuit Breaker Mounting Type | Plug-in to SafePanel® |
Max Steady State Rating | 250 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Branch Circuit Panel Board 1 (PANEL 821)
Rating - Phases | 225 |
Rating - Neutral | 225 |
Rating - Ground | 225 |
Withstand | 22 |
Supplier | Schneider/Square D |
Branch Circuit Panel Board 2 Main Circuit Breaker (CB822)
Frame Rating | 250 |
Circuit Breaker Type | Electronic Trip (LS/I) |
Circuit Breaker Mounting Type | Plug-in to SafePanel® |
Max Steady State Rating | 250 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Branch Circuit Panel Board 2 (PANEL 822)
Rating - Phases | 225 |
Rating - Neutral | 225 |
Rating - Ground | 225 |
Withstand | 22 |
Supplier | Schneider/Square D |
Branch Circuit Panel Board 3 Main Circuit Breaker (CB823)
Frame Rating | 250 |
Circuit Breaker Type | Electronic Trip (LS/I) |
Circuit Breaker Mounting Type | Plug-in to SafePanel® |
Max Steady State Rating | 250 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Branch Circuit Panel Board 3 (PANEL 823)
Rating - Phases | 225 |
Rating - Neutral | 225 |
Rating - Ground | 225 |
Withstand | 22 |
Supplier | Schneider/Square D |
Branch Circuit Panel Board 4 Main Circuit Breaker (CB824)
Frame Rating | 250 |
Circuit Breaker Type | Electronic Trip (LS/I) |
Circuit Breaker Mounting Type | Plug-in to SafePanel® |
Max Steady State Rating | 250 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
Branch Circuit Panel Board 4 (PANEL 824)
Rating - Phases | 225 |
Rating - Neutral | 225 |
Rating - Ground | 225 |
Withstand | 22 |
Supplier | Schneider/Square D |
PANEL 801 Subfeed Circuit Breaker 1
Frame Rating | 400 |
Circuit Breaker Type | Electronic Trip (LS/I) |
Circuit Breaker Mounting Type | Plug-in, (2) 3/0-250 MCM load lugs |
Max Steady State Rating | 300 |
Percent Rating | 80 |
Fault Rating at Rated Voltage | 65kAIC @ 240VAC |
Presence of Shunt Trip | No |
Presence of CB Position Indications | Yes - monitored internally |
Presence of Lockout/Tag-out Bracket | Yes |
Number of Poles | 3 |
Supplier | ABB |
SafePanel® 1 (PANEL 801)
Current | 1200 |
Withstand | 100 |
Supplier | ABB |
Secondary Side SPD (SPD620)
Voltage | 120/208 |
Number of Wires | 4 |
Type | Type 2 SPD |
Surge Withstand | 40 |
Presence of Alarm Indication | Yes - monitored internally |
CB821 Load Side Lug
Type | Mechanical Lug |
Cable Size | (1) 10 AWG-250MCM (Cu Only) |
CB822 Load Side Lug
Type | Mechanical Lug |
Cable Size | (1) 10 AWG-250MCM (Cu Only) |
CB823 Load Side Lug
Type | Mechanical Lug |
Cable Size | (1) 10 AWG-250MCM (Cu Only) |
CB824 Load Side Lug
Type | Mechanical Lug |
Cable Size | (1) 10 AWG-250MCM (Cu Only) |
N1 Neutral Lug 821-1
Type | Compression Lug |
Cable Size | 2/0 AWG |
N1 Neutral Lug 822-1
Type | Compression Lug |
Cable Size | 2/0 AWG |
N1 Neutral Lug 823-1
Type | Compression Lug |
Cable Size | 2/0 AWG |
N1 Neutral Lug 824-1
Type | Compression Lug |
Cable Size | 2/0 AWG |
IN1G-3 Lug 822-1
Type | Compression Lug |
Cable Size | 2 AWG |
G1 Lug 823-1
Type | Compression Lug |
Cable Size | 2 AWG |
G1 Lug 824-1
Type | Compression Lug |
Cable Size | 2 AWG |
Safety Features
The LayerZero eRDP-FSis designed for maximum operator safety. It uses a sectionalized design, which means that the power quality monitoring is housed in a separate section from the circuit breakers and customer cable connections. This compartmentalized design allows the equipment to be safely operated and serviced.
In normal operation, the inner dead-front doors of the HD2 remain closed.
A polycarbonate window in the door allows operators to safely view the circuit breaker positions with the dead front door closed. INSIGHT IR® cameras (optional) or an IR Port (standard) provides the ability to monitor the temperatures of critical connections with the doors safely closed.
The LayerZero Power Systems eRDP-FSis a safe and reliable piece of equipment that is designed to protect operators and equipment.
Reliability Features
The LayerZero eRDP-FSis a highly reliable Remote Power Panel designed to provide power distribution and monitoring for critical applications. It offers advanced safety and reliability features to ensure consistent and dependable power delivery.
The eRDP-FSis built with high-quality components, ensuring long-lasting performance and reliability. HD2 features silver-plated connections, which enhance conductivity and minimize resistance, resulting in optimal power transmission.
With its comprehensive design, the eRDP-FSis capable of meeting the demands of various operating conditions. It incorporates a seismic rating, making it suitable for installations in seismically active areas. This ensures the stability and performance of the panel, even during earthquakes.
The eRDP-FSalso incorporates serialized board tracking, enabling easy identification and tracking of individual boards within the panel. This feature simplifies maintenance and troubleshooting, such as having the ability to detect for part defects.
With its reliable performance, advanced features, and safety-focused design, the LayerZero eRDP-FSis an excellent choice for organizations that require a dependable and safe remote power panel to support their critical applications.
Power Quality Monitoring Features
The LayerZero eRDP-FSis equipped with an advanced Power Quality Monitoring (PQM) system that provides local and remote access using non-proprietary protocols. The PQM system includes basic monitoring, alarms, waveform capture, and ITIC plotting capabilities.
The ITIC plotting utility is used to audit the quality of transfers.
Connectivity Features